Michigan Administrative Code
Department - Licensing and Regulatory Affairs
Bureau of Construction Codes
Construction Code Commission General Rules
Construction Code
Part 5 - RESIDENTIAL CODE
Section R. 408.30516 - Design criteria
Current through Vol. 24-16, September 15, 2024
Rule 516.
Table R301.2(1) of the code is amended and figures R301.2(7) and R301.2(8) are added to the code to read as follows:
TABLE R 301.2(1)
CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
Ground Snow Load |
Wind Speedd (mph) |
Seismic Design Categoryf |
Subject to Damage From |
Winter Design Tempe |
Ice Barrier Underlayment Requiredh |
Flood Hazardsg |
Air Freezing Indexi |
Mean Annual Tempj |
||
Weatheringa |
Frostline depthb |
Termitec |
See Note e |
Yes |
See Note g |
Figure R403.3(2) |
See footnote J |
|||
Table R301.2(5) |
90 |
See Sec.R301.2.2.1 & Figure R301.2(2) |
Severe |
42" See Note b |
Figure R301.2(6) |
For SI: 1 pound per square foot = 0.0479 kN/m2, 1 mile per hour = 1.609 km/h.
(a) Weathering may require a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code. The weathering column shall be filled in with the weathering index (i.e., "negligible", "moderate," or "severe") for concrete as determined from the weathering probability map [figure R301.2(3)]. The grade of masonry units shall be determined from ASTM C 34, C 55, C 62, C 73, C 90, C 129, C 145, C 216 or C 652 as listed in chapter 44.
(b) The frost line depth may be modified as provided in section R403.1.4 of the code.
(c) The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local damage.
(d) The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map [figure R301.2(4)]. Wind exposure category shall be determined on a site-specific basis in accordance with section R301.2.1.4 of the code.
(e) The winter design temperature criteria shall be taken from appendix D of the Michigan plumbing code, R 408.30701 to R 408.30796.
(f) Design category determined from section R301.2.2.1 of the code.
(g) The jurisdiction shall fill in this part of the table with both of the following:
(h) In accordance with sections R905.2.7, R905.4.3.1, R905.5.3.1, R905.6.3.1, R905.7.3.1 and R905.8.3.1 of the code, for areaswhere the average daily temperature in January is 25 degrees Fahrenheit (-4 degrees Celsius) or less, or where there has been a history of local damage from the effects of ice damming, the jurisdiction shall fill in this part of the table with "YES". Otherwise, the jurisdiction shall fill in this part of the table with "NO".
(i) The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index (bf-days) from figureR403.3(2) or from the 100-year (99%) value on the national climatic data center data table "air freezing index-USA method (base 32 degrees Fahrenheit)".
(j) The jurisdiction shall fill in this part of the table with the mean annual temperature from the national climatic data center data table "air freezing index-USA method (base 32 degrees Fahrenheit)" at www.ncdc.noaa.gov/fpsf.html.