Michigan Administrative Code
Department - Licensing and Regulatory Affairs
Bureau of Construction Codes
Construction Code Commission General Rules
Construction Code
Part 4 - BUILDING CODE
Section R. 408.30421 - Emergency escape and rescue
Current through Vol. 24-16, September 15, 2024
Rule 421.
Sections 1025.1 and 1030.1 of the code are amended and 1016.2.2 is added to read as follows:
1016.2.2. Group E. Egress from classrooms in group E occupancies shall be limited to pass through 1 intervening space before reaching an exit access door leading directly to a corridor or an exit.
1025.1. General. Approved luminous egress path markings delineating the exit path shall be provided in buildings with an occupied floor located more than 75 feet (16 764 mm) above the lowest level of fire department vehicle access of groups A, B, E, I, M, and R-I occupancies in accordance with sections 1024.1 to 1024.5.
1030.1. General. In addition to the means of egress required by this chapter, provisions shall be made for emergency escape and rescue in group R occupancies as applicable in section 101.2. Basements and sleeping rooms below the fourth story above grade plane shall have at least 1 exterior emergency escape and rescue opening in accordance with this section. Where basements contain 1 or more sleeping rooms, emergency egress and rescue openings shall be required in each sleeping room, but shall not be required in adjoining areas of the basement. The opening shall open directly into a public street, public alley, yard, or court.
Exceptions: