Michigan Administrative Code
Department - Licensing and Regulatory Affairs
Bureau of Construction Codes
Construction Code Commission General Rules
Construction Code
Part 10 - MICHIGAN UNIFORM ENERGY CODE
Section R. 408.31063a - Specific insulation requirements (prescriptive)

Universal Citation: MI Admin Code R. 408.31063a
Current through Vol. 24-16, September 15, 2024

Rule 1063a Section R402.2.12 of the code is amended to read as follows.

R402.2.12. Thermally isolated sunroom insulation. The minimum ceiling insulation R-values shall be R-24 in zones 5 to 7. The minimum wall R-value shall be R-13 in all zones. New wall or walls separating a sunroom from conditioned space shall meet the building thermal envelope requirements.

Disclaimer: These regulations may not be the most recent version. Michigan may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.