Ionizing Radiation Rules Governing the Use of Radiation Machines
Part 11 - PARTICLE ACCELERATOR INSTALLATIONS
SAFETY REQUIREMENTS FOR THE USE OF PARTICLE ACCELERATORS
Section R. 333.5448 - Accelerator controls and interlock systems

Universal Citation: MI Admin Code R. 333.5448

Current through Vol. 25-4, March 15, 2025

Rule 448.

(1) Instrumentation, readouts, and controls on the accelerator control console shall be clearly identified and easily discernible.

(2) All entrances or openings into a target room or other high radiation area shall be provided with interlocks.

(3) When an interlock system has been tripped, operation of the accelerator shall only be resumed by first manually resetting controls at the position where the interlock has been tripped, and lastly at the main control console.

(4) A safety interlock shall be on a circuit which will allow it to operate independently of all other safety interlocks.

(5) A safety interlock shall be fail safe. A defect or component failure in the interlock system shall prevent operation of the accelerator.

(6) A scram button or other emergency power cutoff switch shall be located and easily identifiable in all high radiation areas. This cutoff switch shall include a manual reset so that the accelerator cannot be restarted from the accelerator control console without resetting the cutoff switch.

Disclaimer: These regulations may not be the most recent version. Michigan may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.