Part 74 - FIREFIGHTING
INSPECTIONS
Section R. 408.17463 - General utility ropes, life safety ropes, harnesses, and auxiliary equipment

Universal Citation: MI Admin Code R. 408.17463

Current through Vol. 24-16, September 15, 2024

Rule 7463.

(1) Life safety rope, harnesses, and auxiliary equipment dedicated for the purpose of supporting people during emergency operations or training for these operations must be used and meet or exceed the requirements of NFPA 1983: "Standard on Life Safety Rope and Equipment for Emergency Services," 2001 edition, as adopted in R 408.17405.

(2) General utility ropes must comply with the following conditions:

(a) A rope must be inspected after each use for all of the following:
(i) Externally for abrasions, cut or broken fibers, decay, burns, lack of strength, softness, variation in size or roundness of the strands, and for mildew or mold.

(ii) Natural fiber ropes must be inspected internally annually, by separating the strands at 3-foot intervals, for broken fibers, presence of grit, mildew or mold, color change of the fibers, or powdering and short, loose fibers.

(b) A rope that has any of the conditions described in subdivision (a) of this subrule must be replaced or repaired.

(c) Ropes must be stored in a dry location.

Disclaimer: These regulations may not be the most recent version. Michigan may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.