Michigan Administrative Code
Department - Labor and Economic Opportunity
MIOSHA
General Industry and Construction Safety and Occupational Health Standards
General Industry Safety Standards
Part 7 - GUARDS FOR POWER TRANSMISSION
POWER TRANSMISSION EQUIPMENT
Section R. 408.10727 - Belts

Universal Citation: MI Admin Code R. 408.10727

Current through Vol. 24-16, September 15, 2024

Rule 727.

(1) A belt and pulley that is 7 feet or less above the floor or platform and that is exposed to contact must be guarded pursuant to R 408.10751 to R 408.10754. In a power plant or power-development room, a guardrail system may be used in compliance with General Industry Safety and Health Standard Part 2. "Walking-Working Surfaces," as referenced in R 408.10702.

(2) A horizontal belt more than 7 feet above the floor or platform must be guarded for its entire length if located over a passageway or work place pursuant to R 408.10753 and figure 2 contained in subrule (5) of this rule.

(3) A passageway between horizontal belts must have a lower run guarded by a platform that is provided with a guardrail system in compliance with General Industry Safety and Health Standard Part 2. "Walking-Working Surfaces," as referenced in R 408.10702, and the upper run guarded pursuant to subrule (2) of this rule.

(4) A vertical or inclined belt running over a lower pulley more than 7 feet above the floor or platform and located over a passageway or work place must be guarded pursuant to subrule (2) of this rule.

(5) Figure 2 reads as follows:

FIGURE 2

Click Here To View Image

Disclaimer: These regulations may not be the most recent version. Michigan may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.