Michigan Administrative Code
Department - Labor and Economic Opportunity
MIOSHA
General Industry and Construction Safety and Occupational Health Standards
General Industry Safety Standards
Part 7 - GUARDS FOR POWER TRANSMISSION
POWER DISCONNECTS AND LOCK-OUTS
Section R. 408.10765 - Inspection and care of equipment; clothing for oilers
Current through Vol. 24-16, September 15, 2024
Rule 765.
(1) All power-transmission equipment shall be inspected at intervals not exceeding 60 days and be kept in good working condition at all times.
(2) Shafting shall be kept in alignment, free from rust and excess oil or grease.
(3) Where explosives, explosive dusts, flammable vapors, or flammable liquids exist, the hazard of static sparks from shafting shall be carefully considered.
(4) Bearings shall be kept in alignment and properly adjusted.
(5) Hangers shall be inspected to make certain that all supporting bolts and screws are tight and that supports of hangers boxes are adjusted properly.
(6) Pulleys shall be kept in proper alignment to prevent belts from running off.
(7) Inspection shall be made of belts, lacings, and fasteners, and such equipment shall be kept in good repair.