Part 59 - HELICOPTERS
Section R. 408.15914 - Briefings; visibility; fires; energized lines or equipment

Universal Citation: MI Admin Code R. 408.15914

Current through Vol. 24-16, September 15, 2024

Rule 5914.

(1) Briefing shall be conducted prior to each day's operation and shall set forth the plan of operation for the pilot in command and ground employees.

(2) The employer shall insure that, when visibility is reduced by dust or other conditions, ground employees are instructed to exercise special caution to keep clear of the main and stabilizing rotors. The employer shall also eliminate, as far as practical, the dust or other conditions reducing the visibility.

(3) Open fires shall not be permitted in areas where they may be spread by the rotor downwash.

(4) A helicopter, or any part of a helicopter, shall maintain the clearances prescribed in table 1 from any energized line or equipment, unless the owner or operator of the line assures that the line is deenergized and visibly grounded.

TABLE 1

Voltage Clearance
50 kilovolts or less 15 feet
More than 50 kilovolts 15 feet plus .4 inch per each kilovolt over 50 kilovolts

Disclaimer: These regulations may not be the most recent version. Michigan may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.