Michigan Administrative Code
Department - Labor and Economic Opportunity
MIOSHA
General Industry and Construction Safety and Occupational Health Standards
General Industry Safety Standards
Part 5 - POWERED PLATFORMS FOR BUILDING MAINTENANCE
WIRE, FIBER AND SYNTHETIC ROPE
Section R. 408.10577 - Control circuits; power circuits; components
Current through Vol. 24-16, September 15, 2024
Rule 577.
(1) Electrical wiring and equipment shall be in compliance with the requirements specified in General Industry Safety Standard Part 39 "Design Safety Standards for Electrical Systems," as referenced in R 408.10509, except as otherwise required by these rules.
(2) An electrical runway conductor system shall be of a type that is designed for use in exterior locations and shall be located so that the system does not come into contact with accumulated snow or water.
(3) Cables shall be protected against damage that results from over-tensioning or from other causes.
(4) Devices shall be included in the control system for the equipment which will provide protection against electrical overloads, 3-phase reversal, and phase failure. The control system shall have a separate method, which shall be independent of the direction control circuit, for breaking the power circuit if there is an emergency or malfunction.
(5) Suspended or supported equipment shall have a control system that will require the operator of the equipment to follow predetermined procedures.
(6) All of the following requirements apply to electrical protection devices: