Part 5 - POWERED PLATFORMS FOR BUILDING MAINTENANCE
WIRE, FIBER AND SYNTHETIC ROPE
Section R. 408.10574 - Maintenance
Universal Citation: MI Admin Code R. 408.10574
Current through Vol. 24-16, September 15, 2024
Rule 574.
(1) The following maintenance shall be performed, when required, during the 30-day inspection:
(a) Replacement of any worn or
defective parts noted during the inspections prescribed in
R
408.10572.
(b) Electrical connections shall be tightened
and controller contactors and relays shall be cleaned.
(c) Gears, shafts, bearings, brakes, and
hoisting drums shall be aligned.
(2) Hoisting ropes shall be reshackled at the non-drum ends at least once every 2 years. In reshackling a rope, enough shall be cut from the end to remove damaged or fatigued portions. The rope shall be retagged and the limit switches reset, if necessary.
(3) Hoisting rope shall be replaced when there are 6 or more broken wires in any 1 lay or when the wire rope becomes damaged or is in a deteriorated condition.
Disclaimer: These regulations may not be the most recent version. Michigan may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.