Section R. 408.10586 - Periodic resocketing of wire rope fastenings

Universal Citation: MI Admin Code R. 408.10586

Current through Vol. 24-16, September 15, 2024

Rule 586.

(1) Hoisting ropes that utilize poured socket fastenings shall be resocketed at the non-drum ends at intervals of not more than 24 months. In resocketing the ropes, a sufficient length shall be cut from the end of the rope to remove damaged or fatigued portions.

(2) Resocketed ropes shall be in compliance with the requirements of R 408.10581.

(3) Limit switches that are affected by the resocketed ropes shall be reset, if necessary.

Disclaimer: These regulations may not be the most recent version. Michigan may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.