Part 5 - POWERED PLATFORMS FOR BUILDING MAINTENANCE
MAINTENANCE
Section R. 408.10583 - Fiber rope maintenance; inspection and replacement
Current through Vol. 24-16, September 15, 2024
Rule 583.
(1) An employer shall ensure that fiber rope shall be inspected visually before the start of each daily use as follows:
(2) A fiber rope shall be stored in a dry room in coils or on a reel.
(3) A wet fiber rope shall be dried by placing it in the sunshine or a warm room hanging loosely over a rounded peg or hook.
(4) A fiber rope shall not be kinked or run over sharp corners, shall not be used when frozen, and shall not be left in freezing temperatures when wet.
(5) A fiber rope that is subjected to an impact load that is equal to or more than its rated capacity shall be replaced.
(6) A thimble shall be used with fiber rope pursuant to the provisions of R 408.10581(2).