Michigan Administrative Code
Department - Labor and Economic Opportunity
MIOSHA
General Industry and Construction Safety and Occupational Health Standards
General Industry Safety Standards
Part 49 - SLINGS
SYNTHETIC WEB SLINGS
Section R. 408.14964 - Use; safe operating temperatures
Universal Citation: MI Admin Code R. 408.14964
Current through Vol. 24-16, September 15, 2024
Rule 4964.
(1) When a synthetic web sling is used, the following precautions shall be taken:
(a) A nylon web sling shall not be used where
fumes, vapors, sprays, mists, or liquids of acids or phenolics are
present.
(b) A polyester and
polypropylene web sling shall not be used where fumes, vapors, sprays, mists,
or liquids of caustics are present.
(c) A web sling with aluminum fittings shall
not be used where fumes, vapors, sprays, mists, or liquids of caustics are
present.
(2) A synthetic web sling of polyester and nylon shall not be used at a temperature in excess of 180 degrees Fahrenheit.
(3) A polypropylene web sling shall not be used at a temperature in excess of 200 degrees Fahrenheit. (See figure 6 "Basic Synthetic Web Sling Constructions.")
FIGURE 6
BASIC SYNTHETIC WEB SLING CONSTRUCTIONS
Disclaimer: These regulations may not be the most recent version. Michigan may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.