Part 44 - FOUNDRIES
Section R. 408.14443 - Cupolas

Universal Citation: MI Admin Code R. 408.14443

Current through Vol. 24-16, September 15, 2024

Rule 4443.

(1) A skip hoist or charging machine, unless completely enclosed, shall be equipped with:

(a) A warning device to announce movement.

(b) An interlocking gate across the bucket loading opening.

(2) An employee working in a cupola shall be protected from falling objects by an overhead guard.

(3) A cupola bottom shall be:

(a) Supported by 2 or more metal props of structural strength with overall safety factor of not less than 10 to support a full capacity load and adjusted to proper height by wedges or screw jacks.

(b) Dropped only after a general warning has been sounded and all persons are removed to a safe distance or protected by a permanent or movable enclosure or screen.

(c) Dropped into an area free of water.

(4) A slag hole shall be shielded to protect an employee from spattering slag.

(5) Where oxygen is used to blow or cut tapping holes, a screen or guard shall be used to protect nearby employees from hot blown material.

(6) An employee not wearing light attenuating goggles or shields shall be protected by a screen or wall from the arc of an electric furnace.

Disclaimer: These regulations may not be the most recent version. Michigan may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.