Rule 3395f. An employer shall ensure that all linemans body belt and pole strap systems meet the following tests:

(a) A dielectric test of 819.7 volts, AC, per centimeter, 25,000 volts per foot, for 3 minutes without visible deterioration.

(b) A leakage test of 98.4 volts, AC, per centimeter, 3,000 volts per foot, with a leakage current of no more than 1 mA.

(c) A flammability test in accordance with Table F "Flammability Test."

TABLE F

FLAMMABILITY TEST

Test Method

Criteria for Passing Test

1. Vertically suspend a 19.7-inch (500-mm) length of strapping supporting a 220.5-lb (100-kg) weight.

Any flames on the position strap must self-extinguish.

2. Use a butane or propane burner with a 3-inch (76-mm) flame.

3. Direct the flame to an edge of the strapping at a distance of 1 inch (25 mm).

The positioning strap must continue to support the 220.5-lb (100-kg) mass.

4. Remove the flame after 5 seconds.

5. Wait for any flames on the positioning strap to stop burning.

Disclaimer: These regulations may not be the most recent version. Michigan may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.