Rule 2353.

(1) Mechanical pedal return springs shall be the compression type, operated on a rod or guided within a hole or tube. If operated on a rod, the inside diameter of the spring shall be no greater than the diameter of the rod, plus 1/8 inch. If guided within a hole or tube, the inside diameter of the hole or tube shall be no greater than the outside diameter of the spring coil, plus 1/8 inch. A spring, in its initial compressed position, shall be so wound that the space between coils is less than the diameter of the wire.

(2) A pedal counterweight, if provided, shall have the path of the travel of the weight enclosed or guarded.

(3) A mechanical foot pedal shall be securely mounted on a press leg where the pedal is an integral part of the press.

Disclaimer: These regulations may not be the most recent version. Michigan may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.