Michigan Administrative Code
Department - Labor and Economic Opportunity
MIOSHA
General Industry and Construction Safety and Occupational Health Standards
General Industry Safety Standards
Part 14 - CONVEYORS
SPECIFIC CONVEYORS
Section R. 408.11449 - Reciprocating conveyors

Universal Citation: MI Admin Code R. 408.11449

Current through Vol. 24-16, September 15, 2024

Rule 1449.

(1) A reciprocating conveyor shall have inside and outside nip points guarded.

(2) If the reciprocating member of a horizontal reciprocating conveyor moves within 18 inches of a wall or other object, a barrier shall be installed at the end to prevent access by an employee.

(3) A vertical reciprocating conveyor which is manually loaded or unloaded shall be guarded with an interlock door or gate to prevent an employee being caught within a nip point.

(4) The carriage and controls of a vertical reciprocating conveyor shall be designed and installed to prevent use of the conveyor as a man lift.

Disclaimer: These regulations may not be the most recent version. Michigan may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.