Part 7 - WELDING AND CUTTING GENERAL PROVISIONS
Section R. 408.40715 - Torches generally

Universal Citation: MI Admin Code R. 408.40715

Current through Vol. 24-16, September 15, 2024

Rule 715.

(1) A torch shall be inspected before each shift for leaking shutoff valves, hose and tip connections, and clogged tips. A defective torch shall not be used.

(2) A clogged tip opening shall be cleaned with a device, such as a drill or cleaning wire, designed for this purpose.

(3) A torch shall be lighted by a friction lighter and not by a match or hot work.

Disclaimer: These regulations may not be the most recent version. Michigan may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.