Michigan Administrative Code
Department - Labor and Economic Opportunity
MIOSHA
General Industry and Construction Safety and Occupational Health Standards
Construction Safety and Health Standard
Part 15 - EXCAVATORS, HOISTS, ELEVATORS, HELICOPTERS, AND CONVEYORS
PERSONNEL HOISTS AND ELEVATORS - ADDITIONAL REQUIREMENTS
Section R. 408.41563 - Bridge tower construction personnel hoists

Universal Citation: MI Admin Code R. 408.41563

Current through Vol. 24-16, September 15, 2024

Rule 1563.

(1) A personnel hoist that is used in bridge tower construction shall be approved by a registered professional engineer and installed in accordance with R 408.41560(2).

(2) When a hoist tower is not enclosed, the car or hoist platform shall be totally enclosed or caged on all sides for the full height between the floor and the overhead protective covering with not less than 3/4-inch mesh of no. 14 U.S. gauge wire or equivalent. The hoist car enclosure shall include the required gates for loading and unloading.

(3) An employer shall ensure that hoists are inspected for defects, serviced, and maintained on a weekly basis, and repaired as necessary. If the hoisting equipment is exposed to winds of more than 35 miles per hour, authorized personnel must inspect and repair the hoisting equipment if necessary before reuse.

Disclaimer: These regulations may not be the most recent version. Michigan may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.