Michigan Administrative Code
Department - Labor and Economic Opportunity
MIOSHA
General Industry and Construction Safety and Occupational Health Standards
Construction Safety and Health Standard
Part 15 - EXCAVATORS, HOISTS, ELEVATORS, HELICOPTERS, AND CONVEYORS
BASE-MOUNTED DRUM HOISTS
Section R. 408.41570 - Base-mounted drum hoists; general requirements
Current through Vol. 24-16, September 15, 2024
Rule 1570.
(1) Exposed moving parts, such as gears, projecting screws, setscrews, chain, cables, chain sprockets, and reciprocating or rotating parts, which constitute a hazard, shall be guarded.
(2) All controls used during the normal operation cycle shall be located within easy reach of the operator's station.
(3) An employer shall ensure that electric motor operated hoists are provided with all of the following:
(4) All base-mounted drum hoists in use shall meet the applicable requirements for design, construction, installation, testing, inspection, maintenance, and operations, as prescribed by the manufacturer.
(5) This rule does not apply to base-mounted drum hoists used in conjunction with derricks. Base-mounted drum hoists used in conjunction with derricks shall conform to Construction Safety Standard Part 10 "Cranes and Derricks," as referenced in R 408.41505.