Part 11 - CONTINUOUS EMISSION MONITORING
Section R. 336.2152 - Cycling time for continuous emission monitoring systems

Universal Citation: MI Admin Code R. 336.2152

Current through Vol. 24-04, March 15, 2024

Rule 1152.

(1) Continuous monitoring systems for measuring opacity shall complete a minimum of 1 cycle of sampling and analyzing for each successive 10-second period and 1 cycle of data recording for each successive 6-minute period.

(2) Continuous monitoring systems for measuring oxides of nitrogen, carbon dioxide, oxygen, or sulfur dioxide shall complete a minimum of 1 cycle of operation for each successive 15-minute period.

Disclaimer: These regulations may not be the most recent version. Michigan may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.