Revise and replace section AT103.3 (RB103.3) Solar-Ready Zone Area as follows:

The total solar-ready zone area shall consist of an area not less than 300 ft2 (27.87 m2) exclusive of mandatory access or set back areas as required by 527 CMR. New multiple single-family dwellings (townhouses) three stories or less in height above grade plane and with a total floor area less than or equal to 2,000 ft2 (185.8 m2) per dwelling shall have a solar-ready zone area of not less than 150 ft2 (13.94 m2). The solar-ready zone shall be composed of areas not less than five feet (1,524 mm) in width and not less than 80 ft2 (7.44 m2) exclusive of access or set back areas as required by 527 CMR.

Disclaimer: These regulations may not be the most recent version. Massachusetts may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.