Chapter 7 - Fire and Smoke Protection Features
Section 718 - FIRE-RESISTANCE REQUIREMENTS FOR PLASTER
Subsection 718.4 - Double reinforcement

Universal Citation: 780 CMR MA Code of Regs 718.4
Current through Register 1531, September 27, 2024

Plaster protection more than 1 inch (25 mm) in thickness shall be reinforced with an additional layer of approved lath embedded at least 3/4 inch (19.1 mm) from the outer surface and fixed securely in place.

Exception: Solid plaster partitions or where otherwise determined by fire tests.

Disclaimer: These regulations may not be the most recent version. Massachusetts may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.