Code of Massachusetts Regulations
780 CMR - STATE BOARD OF BUILDING REGULATIONS AND STANDARDS
Chapter 4 - Special Detailed Requirements Based on Use and Occupancy
Section 408 - GROUP I-3
Subsection 408.5 - Protection of vertical openings
Universal Citation: 780 CMR MA Code of Regs 408.5
Current through Register 1531, September 27, 2024
Any vertical opening shall be protected by a shaft enclosure in accordance with Section 708, or shall be in accordance with Section 408.5.1.
408.5.1 Floor openings. Openings in floors within a housing unit are permitted without a shaft enclosure, provided all of the following conditions are met:
1. The entire normally occupied areas so
interconnected are open and unobstructed so as to enable observation of the
areas by supervisory personnel;
2.
Means of egress capacity is sufficient for all occupants from
all interconnected cell tiers and areas;
3. The height difference between the floor
levels of the highest and lowest cell tiers shall not exceed 23 feet (7010 mm);
and
4. Egress from any portion of
the cell tier to an exit or exit
access door shall not require travel on more than one
additional floor level within the housing unit.
408.5.2 Shaft openings in communicating floor levels. Where a floor opening is permitted between communicating floor levels of a housing unit in accordance with Section 408.5.1, plumbing chases serving vertically stacked individual cells contained with the housing unit shall be permitted without a shaft enclosure.
Disclaimer: These regulations may not be the most recent version. Massachusetts may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.