The values in Table 3412.8 are the required mandatory safety scores for the evaluation process listed in Section 3412.6.
TABLE 3412.8 MANDATORY SAFETY SCORESa
OCCUPANCY |
FIRE
SAFETY (MFS) |
MEANS OF EGRESS (MME) |
GENERAL SAFETY (MGS) |
A-1 | 16 | 27 | 27 |
A-2 | 19 | 30 | 30 |
A-3 | 18 | 29 | 29 |
A-4, E | 23 | 34 | 34 |
B | 24 | 34 | 34 |
F | 20 | 30 | 30 |
M | 19 | 36 | 36 |
R | 17 | 34 | 34 |
S-1 | 15 | 25 | 25 |
S-2 | 23 | 33 | 33 |
a. | MFS = Mandatory Fire Safety; MME = Mandatory Means of Egress; MGS = Mandatory General Safety. |
Disclaimer: These regulations may not be the most recent version. Massachusetts may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.