Code of Massachusetts Regulations
780 CMR - STATE BOARD OF BUILDING REGULATIONS AND STANDARDS
Chapter 34 - Existing Buildings and Structures
Section 3412 - COMPLIANCE ALTERNATIVES
Subsection 3412.8 - Safety scores

Universal Citation: 780 CMR MA Code of Regs 3412.8
Current through Register 1531, September 27, 2024

The values in Table 3412.8 are the required mandatory safety scores for the evaluation process listed in Section 3412.6.

TABLE 3412.8 MANDATORY SAFETY SCORESa

OCCUPANCY FIRE
SAFETY
(MFS)
MEANS OF
EGRESS

(MME)
GENERAL
SAFETY

(MGS)
A-1 16 27 27
A-2 19 30 30
A-3 18 29 29
A-4, E 23 34 34
B 24 34 34
F 20 30 30
M 19 36 36
R 17 34 34
S-1 15 25 25
S-2 23 33 33

a. MFS = Mandatory Fire Safety;
MME = Mandatory Means of Egress;
MGS = Mandatory General Safety.

Disclaimer: These regulations may not be the most recent version. Massachusetts may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.