Membrane structures shall be permitted to be utilized as specified in this section as a portion of buildings of other types of construction. Height and area limits shall be as specified for the type of construction and occupancy of the building.
3102.6.1 Noncombustible membrane. A noncombustible membrane shall be permitted for use as the roof or as a skylight of any building or atrium of a building of any type of construction provided it is at least 20 feet (6096 mm) above any floor, balcony or gallery.
3102.6.1.1
Membrane.
A membrane meeting the fire propagation performance criteria of NFPA 701 shall
be permitted to be used as the roof or as a skylight on buildings of Types IIB,
III, IV and V construction, provided it is at least 20 feet (6096 mm) above any
floor, balcony or gallery.
Disclaimer: These regulations may not be the most recent version. Massachusetts may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.