Section 2512 - EXTERIOR PLASTER
Subsection 2512.5 - Second-coat application

Universal Citation: 780 CMR MA Code of Regs 2512.5
Current through Register 1531, September 27, 2024

The second coat shall be brought out to proper thickness, rodded and floated sufficiently rough to provide adequate bond for the finish coat. The second coat shall have no variation greater than 1/4 inch (6.4 mm) in any direction under a 5-foot (1524 mm) straight edge.

Disclaimer: These regulations may not be the most recent version. Massachusetts may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.