2409.3.1 Glass types. Glass in elevator car enclosures, glass elevator car doors and glass used for lining walls and ceilings of elevator cars shall be laminated glass conforming to Class A in accordance with ANSI Z97.1 or Category II in accordance with CPSC 16 CFR.
Exception: Tempered glass shall be permitted to be used for lining walls and ceilings of elevator cars provided:
1. The glass is bonded to a nonpolymeric
coating, sheeting or film backing having a physical integrity to hold the
fragments when the glass breaks.
2.
The glass is not subjected to further treatment such as sandblasting; etching;
heat treatment or painting that could alter the original properties of the
glass.
3. The glass is tested to
the acceptance criteria for laminated glass as specified for Class A in
accordance with ANSI Z97.l or Category II in accordance with CPSC 16
CFR.
2409.3.2 Surface area. The glass in glass elevator car doors shall be not less than 60 percent of the total visible door panel surface area as seen from the car side of the doors.
Disclaimer: These regulations may not be the most recent version. Massachusetts may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.