Code of Massachusetts Regulations
780 CMR - STATE BOARD OF BUILDING REGULATIONS AND STANDARDS
Chapter 22 - Steel
Section 2206 - STEEL JOISTS
Subsection 2206.4 - Steel joist drawings

Universal Citation: 780 CMR MA Code of Regs 2206.4

Current through Register 1531, September 27, 2024

Steel joist placement plans shall be provided to show the steel joist products as specified on the construction documents and are to be utilized for field installation in accordance with specific project requirements as stated in Section 2206.2. Steel placement plans shall include, at a minimum, the following:

1. Listing of all applicable loads as stated in Section 2206.2 and used in the design of the steel joists and joist girders as specified in the construction documents.

2. Profiles for nonstandard joist and joist girder configurations (standard joist and joist girder configurations are as indicated in the SJI catalog).

3. Connection requirements for:

3.1. Joist supports;

3.2. Joist girder supports;

3.3. Field splices; and

3.4. Bridging attachments.

4. Deflection criteria for live and total loads for non-SJI standard joists.

5. Size, location and connections for all bridging.

6. Joist headers.

Steel joist placement plans do not require the seal and signature of the joist manufacturer's registered design professional.

Disclaimer: These regulations may not be the most recent version. Massachusetts may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.