The registered design professional shall indicate on the construction documents the steel joist and/or steel joist girder designations from the specifications listed in Section 2206.1 and shall indicate the requirements for joist and joist girder design, layout, end supports, anchorage, non-SJI standard bridging, bridging termination connections and bearing connection design to resist uplift and lateral loads. These documents shall indicate special requirements as follows:

1. Special loads including:

1.1. Concentrated loads;

1.2. Nonuniform loads;

1.3. Net uplift loads;

1.4. Axial loads;

1.5. End moments; and

1.6. Connection forces.

2. Special considerations including:

2.1. Profiles for nonstandard joist and joist girder configurations (standard joist and joist girder configurations are as indicated in the SJI catalog);

2.2. Oversized or other nonstandard web openings; and

2.3. Extended ends.

3. Deflection criteria for live and total loads for non-SJI standard joists.

Disclaimer: These regulations may not be the most recent version. Massachusetts may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.