Chapter 17 - Structural Tests and Special Inspections
Section 1707 - SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE
Subsection 1707.2 - Structural steel
Universal Citation: 780 CMR MA Code of Regs 1707.2
Current through Register 1531, September 27, 2024
Special inspection for structural steel shall be in accordance with the quality assurance plan requirements of AISC 341.
Exceptions:
1. Special inspections of structural steel in structures assigned to Seismic Design Category C that are not specifically detailed for seismic resistance, with a response modification coefficient, R, of 3 or less, excluding cantilever column systems.
2. For ordinary moment frames, ultrasonic and magnetic particle testing of complete joint penetration groove welds are only required for demand critical welds.
Disclaimer: These regulations may not be the most recent version. Massachusetts may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.