Sliding snow from an adjacent sloping high roof need not be considered on the low roof if snow guards, as specified herein, are provided on the high roof In this case, the sloping roof with snow guards shall be designed for the unit snow loads required for a flat roof The roof area(s) requiring snow guards shall be indicated on the construction documents. Snow guards shall be designed by a registered design professional. The registered design professional shall insure that there are adequate load paths from the snow guards into the supporting members and from the supporting members into the primary structure. The structural design of snow guards shall account for the impact of the sliding snow. The effectiveness in preventing the sliding of snow of proprietary snow guard systems shall be demonstrated by tests.

Disclaimer: These regulations may not be the most recent version. Massachusetts may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.