Code of Massachusetts Regulations
780 CMR - STATE BOARD OF BUILDING REGULATIONS AND STANDARDS
Chapter 15 - Roof Assemblies and Rooftop Structures
Section 1507 - REQUIREMENTS FOR ROOF COVERINGS
Subsection 1507.4 - Metal roof panels
Current through Register 1531, September 27, 2024
The installation of metal roof panels shall comply with the provisions of this section.
1507.4.1 Deck requirements. Metal roof panel roof coverings shall be applied to a solid or closely fitted deck, except where the roof covering is specifically designed to be applied to spaced supports.
1507.4.2 Deck slope. Minimum slopes for metal roof panels shall comply with the following:
1507.4.3 Material standards. Metal-sheet roof covering systems that incorporate supporting structural members shall be designed in accordance with Chapter 22. Metal-sheet roof coverings installed over structural decking shall comply with Table 1507.4.3(1). The materials used for metal-sheet roof coverings shall be naturally corrosion resistant or provided with corrosion resistance in accordance with the standards and minimum thicknesses shown in Table 1507.4.3(2).
TABLE 1507.4.3(1) METAL ROOF COVERINGS
ROOF COVERING TYPE |
STANDARD APPLICATION
RATE/THICKNESS |
Aluminum | ASTM B 209, 0.024 inch minimum thickness for roll-formed panels and 0.019 inch minimum thickness for press-formed shingles. |
Aluminum-zinc alloy coated steel | ASTM A 792 AZ 50 |
Cold-rolled copper | ASTM B 370 minimum 16 oz./sq. ft. and 12 oz./sq. ft. high yield copper for metal-sheet roof covering systems: 12 oz/sq. ft. for preformed metal shingle systems. |
Copper | 16 oz./sq. ft. for metal-sheet roof-covering systems; 12 oz./sq. ft. for preformed metal shingle systems. |
Galvanized steel | ASTM A 653 G-90 zinc-coateda. |
Hard lead | 2 lbs./sq. ft. |
Lead-coated copper | ASTM B 101 |
Prepainted steel | ASTM A 755 |
Soft lead | 3 lbs./sq. ft. |
Stainless steel | ASTM A 240, 300 Series Alloys |
Steel | ASTM A 924 |
Terne and terne-coated stainless |
Terne coating of 40 lbs. per double base box, field
painted where applicable in accordance with manufacturer's installation instructions. |
Zinc | 0.027 inch minimum thickness; 99.995% electrolytic high grade zinc with alloy additives of copper (0.08% - 0.20%), titanium (0.07% - 0.12%) and aluminum (0.015%). |
For SI: 1 ounce per square foot = 0.305
kg/m2, 1 pound per square foot = 4.882
kg/m2, 1 inch = 25.4 mm, 1 pound = 0.454 kg.
a. For Group U buildings, the minimum coating thickness for ASTM A 653 galvanized steel roofing shall be G-60. |
TABLE 1507.4.3(2) MINIMUM CORROSION RESISTANCE
55% Aluminum-zinc alloy coated steel | ASTM A 792 AZ 50 |
5% Aluminum alloy-coated steel | ASTM A 875 GF60 |
Aluminum-coated steel | ASTM A 463 T2 65 |
Galvanized steel | ASTM A 653 G-90 |
Prepainted steel | ASTM A 755a |
a. Paint systems in accordance with ASTM A 755 shall be applied over steel products with corrosion resistant coatings complying with ASTM A 463, ASTM A 653, ASTM A 792 or ASTM A 875. |
1507.4.4 Attachment. Metal roof panels shall be secured to the supports in accordance with the approved manufacturer's fasteners. In the absence of manufacturer recommendations, the following fasteners shall be used: