Code of Massachusetts Regulations
780 CMR - STATE BOARD OF BUILDING REGULATIONS AND STANDARDS
Chapter 115 - Appendices
Appendix C - Group U - Agricultural Buildings
Section C102 - ALLOWABLE HEIGHT AND AREA
Subsection C102.1 - General

Universal Citation: 780 CMR MA Code of Regs C102.1
Current through Register 1531, September 27, 2024

Buildings classified as Group U Agricultural shall not exceed the area or height limits specified in Table C102.1.

TABLE C102.1-BASIC ALLOWABLE AREA FOR A GROUP U, ONE STORY IN HEIGHT AND MAXIMUM HEIGHT OF SUCH OCCUPANCY

I II III and IV V
A B A B III A and IV III B A B
ALLOWABLE AREA (square feet)a
Unlimited 60,000 27,100 18,000 27,100 18,000 21,100 12,000
MAXIMUM HEIGHT IN STORIES
Unlimited 12 4 2 4 2 3 2
MAXIMUM HEIGHT IN FEET
Unlimited 160 65 55 65 55 50 40

For SI: 1 square foot = 0.0929 m2.
a. See Section C102 for unlimited area under certain conditions.

Disclaimer: These regulations may not be the most recent version. Massachusetts may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.