Code of Massachusetts Regulations
780 CMR - STATE BOARD OF BUILDING REGULATIONS AND STANDARDS
Chapter 115 - Appendices
Appendix AA - Stretch Energy Code
Section AA103 - NEW BUILDINGS
Subsection AA103.2 - Large Area and High Energy Use Buildings
Universal Citation: 780 CMR MA Code of Regs AA103.2
Current through Register 1531, September 27, 2024
All buildings over 100,000 ft2, and new supermarkets, laboratories and conditioned warehouses over 40,000 ft2 shall comply with 780 CMR 13.00: Energy Efficiency and shall demonstrate energy use per square foot at least 10% below the energy requirements of ANSI/ASHRAE/IESNA 90.1 APPENDIX G-2013 Performance Rating Method on either a site or source energy basis. The additional Efficiency Package Options selected per C406.1 shall be included in calculating the baseline building performance value.
Exception: Exclusively R-use buildings complying with AA103.1 dwelling unit requirements.
Disclaimer: These regulations may not be the most recent version. Massachusetts may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.