Code of Massachusetts Regulations
524 CMR - BOARD OF ELEVATOR REGULATIONS
Title 524 CMR 35.00 - Safety Code For Elevators And Escalators A17-2004 And The Massachusetts Modifications Of That Code
Part 3 - HYDRAULIC ELEVATORS
Section 3.17 - CAR AND COUNTERWEIGHT SAFETIES

Current through Register 1531, September 27, 2024

3.17.1 Car Safeties Add an additional sentence in the first paragraph as follows: "On roped hydraulic elevators with governor-operated safeties, access to the governor may be omitted if the governor is self-resetting, releases when the car is raised, and can be electrically tripped from the machine room. Governor operation of roped hydraulic safeties may be omitted if a safety valve is installed at the jack casing. The safeties will continue to function as broken rope safeties."

Disclaimer: These regulations may not be the most recent version. Massachusetts may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.