Code of Massachusetts Regulations
524 CMR - BOARD OF ELEVATOR REGULATIONS
Title 524 CMR 29.00 - Stage, Orchestra, and Organ Console Equipment
Section 29.12 - Safety Factor and Hoistway Requirements

Universal Citation: 524 MA Code of Regs 524.29

Current through Register 1518, March 29, 2024

(1) Elevator Platform Construction. The platform shall be of steel frame construction designed with a safety factor of not less than six based on the rated load, uniformly distributed. All other parts of the equipment shall have a safety factor as required by 524 CMR 35.00: Safety Code for Elevators and Escalators A17.1-2013 and the Massachusetts Modifications of That Code.

(2) Installations in the Same Hoistway. When installations are in the same hoistway the adjacent sides shall be provided with solid dividing wall partitions with not less than % hour fire resistive construction.

(3) When travel extends above the top of the hoistway enclosure, aprons of substantial construction shall be provided on the platform of sufficient depth to enclose the space between the top of the hoistway enclosure and the underside of the platform plus three inches when the platform is at its limit of travel.

(4) The lower edge of the aprons shall be beveled at an angle of at least 75 with the horizontal.

Disclaimer: These regulations may not be the most recent version. Massachusetts may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.