Section 26.17 - Requirements for Suspension Means
Current through Register 1531, September 27, 2024
The suspension means for electric and hydraulic elevators shall conform to 524 CMR 35.00: Safety Code for Elevators and Escalators A17.1-2013 and the Massachusetts Modifications of That Code. Car platforms may be suspended by wire ropes attached to each corner of the platform, subject to the following:
(1) A center car frame conforming in all respects to 524 CMR 35.00: Safety Code for Elevators and Escalators A17.1-2013 and the Massachusetts Modifications of That Code shall be provided except that the car crosshead may be omitted, providing:
(2) The car safety required by 524 CMR 26.12 is mounted on the center car frame located as required in 524 CMR 35.00: Safety Code for Elevators and Escalators A17.1-2013 and the Massachusetts Modifications of That Code.
(3) The car safety shall be operated by a speed governor.