Code of Massachusetts Regulations
524 CMR - BOARD OF ELEVATOR REGULATIONS
Title 524 CMR 26.00 - Certain Elevator Equipment Used as Motor Vehicle Parking Devices
Section 26.16 - Terminal Stopping Devices and Operating and Control Devices
Current through Register 1531, September 27, 2024
(1) Terminal stopping devices shall conform to the requirements of 524 CMR 35.00: Safety Code for Elevators and Escalators A17.1-2013 and the Massachusetts Modifications of That Code for hydraulic elevators, provided that roped hydraulic elevators shall have a separate automatic stop valve that is both independent of the normal control valve and mechanically operated directly by the movement of the car.
(2) Operating and control devices shall conform to the requirements of 524 CMR 35.00: Safety Code for Elevators and Escalators Al 7.1-2013 and the Massachusetts Modifications of That Code for electric elevators and for hydraulic elevators in addition to the following:
(3) Class III elevator cars shall be provided with a constant pressure operating device for operating the car for inspection, maintenance, and during emergencies, which shall be operative only when the operating device at the control dispatching station is inoperative. Means shall be provided at the central dispatching station for disconnecting the normal operating device and for making the constant pressure operating device in the car operative.