Code of Massachusetts Regulations
524 CMR - BOARD OF ELEVATOR REGULATIONS
Title 524 CMR 26.00 - Certain Elevator Equipment Used as Motor Vehicle Parking Devices
Section 26.14 - Roped Hydraulic Elevators
Current through Register 1531, September 27, 2024
(1) Piston rods of roped hydraulic elevators shall be so constructed and so roped that the piston shall be stopped before the car can be drawn into the overhead structure. Travel limiting stops of ample strength shall be provided in the cylinder to bring the piston to rest under full pressure without damage to the cylinder assembly or hydraulic system. Such stops shall be of the solid metal to metal type.
(2) Traveling sheaves of roped hydraulic elevators shall be guided in metal guides. Sheave frames, where used, shall be of structural or forged steel having an elongation of not less than 14% in a length of two inches and shall be designed and constructed with a factor of safety of at least eight. A single continuous strap shall not be used for the sheave frame.
(3) Cylinders, valves, piping, connections and tanks shall conform to the requirements of 524 CMR 35.00: Safety Code for Elevators and Escalators A17.1-2013 and the Massachusetts Modifications of That Code. Piston rods of roped hydraulic elevators shall conform to the following:
W = 7500A
Where: W =Allowable gross load, pounds applied to piston rod
A = Net cross sectional area at root of threads in square inches