Code of Massachusetts Regulations
521 CMR - Architectural Access Board
Title 521 CMR 30 - PUBLIC TOILET ROOMS
Section 30.7 - WATER CLOSETS

Current through Register 1531, September 27, 2024

That are required to be accessible shall comply with the following:

30.7.1 Clear floor space: Clear floor space for water closets not in stalls shall comply with Fig. 30d. Clear floor space may be arranged to allow either a left-handed or right-handed approach to the water closet.

Click to view image

30.7.2 Location: The center line of the water closet shall be located 18 inches (18"= 457mm) from the nearest side wall and at least 42 inches (42" = 1067mm) from the farthest side wall or the closest edge of an adjacent fixture. There shall be at least 42 inches (42" = 1067mm) clearance between the front edge of the water closet and the nearest wall or fixture.

30.7.3 Height: Water closets shall be 17 inches to 19 inches (17" to 19" = 432mm to 483mm) high, measured to the top of the water closet seat. See Fig. 30e.

Click to view image

30.7.4 Seats: Water closet seats shall not be spring mounted to return to a lifted position.

30.7.5 Flush Controls: Flush controls shall be hand operated or automatic and shall comply with 521 CMR 39.5, Operation. Controls for flush valves shall be mounted on the wide side of water closet no more than 44 inches (44" = 1120mm) above the floor.

30.7.6 Toilet Paper Dispensers: Toilet paper dispensers shall be located on the side wall closest to the water closet. The centerline of the roll shall be set at a minimum height of 24 inches (24" = 610mm) above the floor. Dispensers that control delivery or that do not permit continuous paper flow are not allowed.

Disclaimer: These regulations may not be the most recent version. Massachusetts may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.