Code of Massachusetts Regulations
521 CMR - Architectural Access Board
Title 521 CMR 30 - PUBLIC TOILET ROOMS
Section 30.17 - CHILDREN'S URINALS

Current through Register 1531, September 27, 2024

Where one or more urinal is provided, at least one urinal shall be accessible.

30.17.1 Height: The accessible urinal shall be stall-type or wall-hung with an elongated rim at a maximum of 15 inches (15" = 381mm) above the finish floor.

30.17.2 Flush Controls: Flush controls shall be hand operated or automatic, and shall be mounted no more than 44 inches (44" = 1120mm) above the finish floor.

Disclaimer: These regulations may not be the most recent version. Massachusetts may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.