Code of Massachusetts Regulations
521 CMR - Architectural Access Board
Title 521 CMR 30 - PUBLIC TOILET ROOMS
Section 30.10 - URINALS
Current through Register 1531, September 27, 2024
Where one or more urinals is provided, at least one urinal shall be accessible. See Fig. 30i.
30.10.1 Height: Accessible urinals shall be stall-type or wall-hung with an elongated rim at a maximum of 17 inches (17" = 432mm) above the finish floor.
30.10.2 Clear floor space: A clear floor space shall be provided in front of an accessible urinal to allow forward approach. This clear space shall adjoin or overlap an accessible route and shall comply with 521 CMR 6.3, Wheelchair Turning Space. Urinal shields that do not extend beyond the front edge of the urinal rim may be provided with 29 inches (29" = 73 7mm) clearance between them.
30.10.3 Flush Controls: Flush controls shall be hand operated or automatic, and shall comply with521 CMR 39.5, Operation and shall be mounted no more than 44 inches (44" = 1118mm) above the finish floor. See Fig. 30i