Code of Massachusetts Regulations
521 CMR - Architectural Access Board
Title 521 CMR 29 - FLOOR SURFACES
Section 29.2 - LEVEL CHANGES

Current through Register 1531, September 27, 2024

Ground and floor surfaces shall be of a common level throughout, except for the following permitted changes in level.

29.2.1 Changes in level up to and including 1/4 inch (1/4" = 6mm) may be vertical and without edge treatment. See Fig. 29a.

29.2.2 Changes in level greater than 1/4 inch (1/4" = 6mm) and less than 1/2 inch (1/2" = 13mm) shall be beveled with a slope no greater than one-in-two (1:2) (50%). See Fig. 29a.

29.2.3 Changes in level greater than 1/2 inch (1/2" = 13mm) are not allowed unless a ramp, walkway, or means of vertical access complying with 521 CMR is provided.

Click to view image

Disclaimer: These regulations may not be the most recent version. Massachusetts may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.