Code of Massachusetts Regulations
521 CMR - Architectural Access Board
Title 521 CMR 28 - ELEVATORS
Section 28.4 - HALL LANTERNS

Current through Register 1531, September 27, 2024

A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call. Lanterns shall comply with the following:

28.4.1 Hall lantern fixtures shall be mounted so that their centerline is at least 72 inches (72" = 1829mm) above the lobby floor. See Fig. 28a.

28.4.2 Audible signals shall sound once for the up direction and twice for the down direction or shall have verbal annunciators that say "up" and "down."

28.4.3 Visible signals shall have the following features:

a. Visual elements shall be at least 21/2 inches (21/2" = 64mm) in the smallest dimension.

b. Signals shall be visible from the vicinity of the hall call button. See Fig. 28a. In-car lanterns located in cars, visible from the vicinity of hall call buttons, and conforming to the above requirements, shall be acceptable.

Disclaimer: These regulations may not be the most recent version. Massachusetts may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.