All doorways and openings that are required to be accessible shall have a clear opening of not less than 32 inches (32" = 813mm). Clear opening of a door is measured from the face of the stop on the latch side to the face of the door when the door is open 90 degrees. For door types such as bifold, accordion, and pocket, the clear opening is measured when the door is in its most fully open position. See Fig. 26b and 26c.

Click to view image

NOTE: A standard 36 inch (36" = 914mm) door with a standard hinge, will produce a clear opening of at least 32 inches (32"= 813mm).

Click to view image

Disclaimer: These regulations may not be the most recent version. Massachusetts may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.