Code of Massachusetts Regulations
521 CMR - Architectural Access Board
Title 521 CMR 26 - DOORS AND DOORWAYS
Section 26.10 - THRESHOLDS
Universal Citation: 521 CMR 26 MA Code of Regs 26.10
Current through Register 1531, September 27, 2024
Thresholds at doorways shall comply with the following (See Fig. 26h):
26.10.1 Thresholds shall not exceed 1/2 inch (1/2" = 13mm) in height and shall be beveled on both sides with a slope no greater than one-in-two (1:2) (50%).
26.10.2 Changes in floor finish materials shall have an edge strip or threshold that is beveled at a ratio of one-in-two (1:2) (50%).
26.10.3 Exterior sliding door thresholds shall not exceed 3/4 of an inch (3/4" =19mm) in height and shall be beveled both sides with a slope no greater than one-in-four (1:4) (25%).
Disclaimer: These regulations may not be the most recent version. Massachusetts may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.