Code of Massachusetts Regulations
105 CMR - DEPARTMENT OF PUBLIC HEALTH
Title 105 CMR 410.000 - Minimum Standards of Fitness for Human Habitation, State Sanitary Code, Chapter II
Section 410.501 - Weathertight Elements
Universal Citation: 105 MA Code of Regs 105.410
Current through Register 1531, September 27, 2024
(A) A window shall be considered weathertight only if:
(1) all
panes of glass are in place, unbroken and properly caulked; and
(2) the window opens and closes fully without
excessive effort; and
(3) exterior
cracks between the prime window frame and the exterior wall are caulked;
and
(4) one of the following
conditions is met:
(a) a storm window is
affixed to the prime window frame, with caulking installed so as to fill
exterior cracks between the storm window frame and the prime window frame;
or
(b) weatherstripping is applied
such that the space between the window sash and the prime window frame is no
larger than 1/16 inch at any point on the perimeter of the sash, in the case of
double hung windows and 1/32 inch in the case of casement windows; or
(c) the window sash is sufficiently
well-fitted such that, without weatherstripping, the space between the window
sash and the prime window frame is no larger than 1/16 inch at any point on the
perimeter of the sash in the case of double hung windows and 1/32 inch in the
case of casement windows.
(B) An exterior door or a door leading from a dwelling unit to a common passageway shall be considered to be weathertight only if:
(1) all panes of glass are in place,
unbroken and properly caulked; and
(2) the door opens and closes fully without
excessive effort; and
(3) exterior
cracks between the prime door frame and the exterior wall are caulked;
and
(4) one of the following
conditions is met:
(a) a storm door is affixed
to the prime door frame, with caulking installed so as to fill exterior cracks
between the storm door frame and the prime door frame; or
(b) weatherstripping is applied such that the
space between the door and the prime door frame is no larger than 1/16 inch at
any point on the perimeter of the door or
(c) the door is sufficiently well-fitted such
that, without weather-stripping, the space between the door and the prime door
frame is no larger than 1/16 inch at any point on the sides of the door or c
inch at any point on the top or bottom of the door.
(C) A wall, floor, ceiling or other structural element shall be considered weathertight only if all cracks and spaces not part of heating, ventilating or air conditioning systems are caulked or filled in as to prevent infiltration of exterior air or moisture.
Disclaimer: These regulations may not be the most recent version. Massachusetts may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.