Code of Massachusetts Regulations
105 CMR - DEPARTMENT OF PUBLIC HEALTH
Title 105 CMR 410.000 - Minimum Standards of Fitness for Human Habitation, State Sanitary Code, Chapter II
Section 410.160 - Heating Systems

Universal Citation: 105 MA Code of Regs 105.410

Current through Register 1531, September 27, 2024

(A) The owner shall provide and maintain in good operating condition a heating system that includes a distribution system capable of heating every habitable room and every room containing a toilet, shower, or bathtub to such temperature required by 105 CMR 410.180.

(B) The following shall not meet the requirements of a heating system:

(1) Fireplace;

(2) Wood or pellet stove; or

(3) Portable electric space heater.

(C) The following are prohibited from use in any residence:

(1) Any portable space heater that has a barometric fed fuel control and a fuel supply tank located less than 42 inches from the center of the burner including, but not limited to, parlor heaters, cabinet heaters, or room heaters;

(2) Heating appliances adapted for burning propane, kerosene, range oil or number one fuel oil;

(3) Portable wick type space heaters; and

(4) Unvented propane or natural gas-fired space heaters not approved in accordance with 527 CMR 1.00: Massachusetts Comprehensive Fire Safety Code.

Disclaimer: These regulations may not be the most recent version. Massachusetts may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.