Code of Massachusetts Regulations
105 CMR - DEPARTMENT OF PUBLIC HEALTH
Title 105 CMR 180.000 - The Operation, Approval And Licensing Of Clinical Laboratories
Section 180.430 - Standard - Histocompatibility: Quality Control
Current through Register 1531, September 27, 2024
In addition to the standards for quality control in immunohematology ( 105 CMR 180.410) and immunology ( 105 CMR 180.400) , which are applicable to the histocompatibility testing laboratory, the histocompatibility testing laboratory shall use the following control systems and validation methods for the performance of tests:
(A) Renal Allotransplantation
(B) The tests in 105 CMR 180.430(A)(2) and (3) are required for transfusions and bone marrow transplants.
(C) For disease associated antigens, 105 CMR 180.430(A)(2) applies only to those antigens for which testing is performed.
(D) Mixed lymphocyte cultures or other recognized methods to detect cellular-defined antigens shall be performed in accordance with prescribed methods. Procedures shall be established for freezing of lymphocytes and to provide for a comprehensive panel of fresh and/or frozen lymphocytes.
(E) Procedures shall be established for the performance of cell harvesting, viability testing and purity checks on lymphocyte suspensions. Such checks shall be done for each test performed.
(F) Provisions for twenty-four hour laboratory coverage shall be maintained for organ transplant testing.
(G) The laboratory shall also: